Kavana

NASDAQ: WLDS

NASDAQ: WLDS

Captures Hand Pose, Force and Intent where cameras can't

Captures Hand Pose, Force and Intent where cameras can't

Captures Hand Pose, Force and Intent where cameras can't

Kavana™ sensing technology | Wearable Devices Ltd.

Kavana™ sensing technology | Wearable Devices Ltd.

Kavana™ sensing technology | Wearable Devices Ltd.

The Challenges

The Challenges

The Challenges

What cameras miss, EMG captures

What cameras miss, EMG captures

What cameras miss, EMG captures

Dexterous manipulation is a bottleneck in robotics. Today it’s captured with vision alone - egocentric and palm cameras - which fail in different ways:

Use Kavana to scale up

Use Kavana to scale up

Use Kavana to scale up

Fuse our EMG-based neural wristband with any egocentric camera array. No gloves, no line-of-sight dependency, no additional rigs.

Fuse our EMG-based neural wristband with any egocentric camera array. No gloves, no line-of-sight dependency, no additional rigs.


Train on the right Data, not on a partial snapshot

Train on the right Data, not on a partial snapshot

Papers comparing vision-only with vision + touch

36 head-to-head comparisons · grey = before VLAs

3

2023 · VLAs introduced

5

11

17

2018–22

2024

2025

2026

2018, 2019 and 2022: one paper each, pooled.

Touch uplift: success with touch ÷ vision-only

Median · whiskers = interquartile range

3.0×

2023 · VLAs introduced

2.0×

1.8×

2.2×

2018–22

2024

2025

2026

Our Hardware

Our Hardware

Our Hardware

Two bands, one platform. Mudra Ultimate is the research-grade capture band for physical-AI data programs. Mudra Pro is the light, everyday band for research labs and academic groups.

Specs

Specs

Specs

Mudra Pro

Mudra Ultimate

General

Mudra Pro

Mudra Ultimate

Weight

38g

43g

Fit

adjustable fit

adjustable fit

EMG

Mudra Pro

Mudra Ultimate

Channels

3 ch

8 ch

Sample rates

200 · 400 · 800 · 1600 · 2133 · 3200 · 4267 · 6400 Hz

500 · 1000 · 2000 · 4000 Hz

Noise floor

TBD

3.0 µVrms

at 500 Hz

4.1 µVrms

at 1000 Hz

6.1 µVrms

at 2000 Hz

12.5 µVrms

at 4000 Hz

DRL

Included

Included

Resolution

24 bit

24 bit

IMU

Mudra Pro

Mudra Ultimate

Type

6-DoF

6-DoF

Resolution

16 bit

16 bit

Sample rate

25 · 50 · 100 · 200 · 400 · 800 · 1600 Hz

25 · 50 · 100 · 200 · 400 · 800 · 1600 Hz

Gyroscope range

±500 dps

±500 dps

Accelerometer range

±4 g

±4 g

PPG

Mudra Pro

Mudra Ultimate

Sampling rates

25 · 50 · 100 · 200 · 400 Hz

25 · 50 · 100 · 200 · 400 Hz

Resolution

24 bit

24 bit

Connectivity

Mudra Pro

Mudra Ultimate

Data streaming

USB-C + BLE

USB-C + BLE / Wi-Fi

Internal SD

Optional

Optional

Software

Mudra Pro

Mudra Ultimate

SDK

Python · C++

Python · C++

Features

Fully Agentic · Lab Streaming Layer (LSL)

Fully Agentic · Lab Streaming Layer (LSL)

Platforms

Windows · macOS · Linux

Windows · macOS · Linux

Join us in building the

human layer of physical AI.

Join us in building thehuman layer of physical AI.

Join us in building the

human layer of physical AI.

How a programme runs

We reply within two working days. No newsletter.

Kavana is the physical AI unit of Wearable Devices Ltd. (Nasdaq: WLDS)